| INPUT |
| Input voltage |
(~3 Phase) 230-500V (-20% to +10%)
(~3 Phase) 690V (-20% to +10%) |
| Supply frequency |
47 to 62 Hz |
| Control voltage |
230V ±10%, others under demand |
| |
|
| OUTPUT |
| Output voltage |
0 to 100% supply voltage |
| Output frequency |
Same as the input |
| Efficiency (at full load) |
> 99% |
| |
|
| ENVIRONMENTAL CONDITIONS |
| Ambient temperature |
Minimum: -10°C / Maximum: +50°C |
| Storage Temperature |
0°C to +70°C |
| Ambient Humidity |
< 95%, non-condensing |
| Altitude losses |
>1000m, 1% each 100m; 3000m max |
| Protection degree |
IP20 |
| Degree of Pollution |
Degree of Pollution 3 |
| |
|
| MOTOR PROTECTIONS |
| Input phase missing |
| High current |
| Low input voltage |
| Starting limit current |
| Rotor locked |
| Motor overload (thermal model) |
| Underload |
| Phase imbalance |
| Motor overtemperature (PTC, normal status 150R-2k7Ω) |
| Shearpin current |
| Number of start /hour |
| |
|
| SOFTSTARTER PROTECTIONS |
| Thyristor fault |
| V5 over temperature |
| |
|
| ADJUSTMENTS |
| Torque surge |
| Initial torque |
| Initial torque time |
| Acceleration time |
| Current limit: 1 to 5 In |
| Overload: 0.8 to 1.2 In, Overload slope: 0 to 10 |
| Deceleration time / Freewheel stop |
| DC braking |
| Slow Speed (1/7 fundamental frequency) |
| Dual setting |
| Number of starts allowed |
| Torque control |
| Water hammer surge control stop |
| For additional information consult the technical manual |
| |
|
| INPUT SIGNALS |
| 2 analogue inputs, 0-20mA or 4-20mA, 0-10V |
| 5 configurable digital inputs |
| 1 PTC input |
| |
|
| OUTPUT SIGNALS |
| 1 output signal 0-20mA or 4-20mA |
| 3 changeover output relays (250VAC, 10A non inductive) |
| |
|
| SERIAL COMMUNICATIONS |
| Phisical level RS232/RS485 |
| Modbus communication industrial protocol |
| Profibus and DeviceNet via interface (options) |
| |
|
| DISPLAYED INFORMATION |
| Phase current |
| Supply voltage |
| Relays status |
| Digital inputs / PTC status |
| Analogue inputs value |
| Analogue output value |
| Overload status |
| Motor supply frequency |
| Motor power factor |
| Developed power, motor shaft torque |
| Fault history (5 most recent faults) |
| |
|
| SOURCES CONTROL |
| Local via keypad |
| Remote via digital inputs |
| Remote via Serial Communications (MODBUS, RS232/RS485) |
| |
|
| LED'S INDICATIONS |
| LED 1 Green, voltage present on control board |
LED 2 Orange, Blinking, Motor accelerating / decelerating
On, motor running |
| LED 3 Red, fault present |
| |
|